Heat Pump in an Ice Storm or Power Outage: What to Do (Pacific Northwest Guide)

Freezing rain is falling, trees are cracking under the weight of the ice, and the lights just flickered. Your heat pump is out there in the middle of it. Should you turn it off? Switch to emergency heat? Throw a tarp over it?

If you lived through the January 2024 ice storm, you know how fast this can happen here. OPB reported downed trees and power lines across the Portland area, widespread power outages, and I-84 closed in the Columbia River Gorge.

The good news: heat pumps are built for winter, and a few smart moves before, during, and after a storm can protect yours from expensive damage. This guide from RHCC walks you through exactly what to do, including the one restart step most homeowners have never heard of.

Key Takeaways

  • Don’t turn your heat pump off just because ice is falling. Its defrost cycle is built to handle light ice.
  • Switch to emergency heat only when the unit is badly iced: ice blocking the fan, the fan hitting ice, or no heat coming out.
  • Only cover the top of the unit. Never wrap the sides.
  • After a power outage longer than 30 minutes, don’t jump straight back to normal heat. Follow the restart steps below to protect the compressor.
  • Run generators outdoors only, more than 20 feet from windows, doors, and vents.


Before the Storm: 6 Things to Do Now

When freezing rain is in the forecast, take 20 minutes to get ready:

  1. Check the gutters above your heat pump. Water dripping from a gutter or roof edge onto the unit can freeze into a thick shell. Redirect it if you can.
  2. Clear 2 feet around the unit. Remove leaves, branches, and anything that could blow into it. Trim back shrubs.
  3. Look at what’s overhead. Ice-heavy branches above the unit can snap and land on it. Note them now, and call an arborist after the storm if needed.
  4. Find your outdoor disconnect and breaker. The disconnect is usually a small box on the wall near the outdoor unit. Know which breaker in your panel controls the heat pump.
  5. Know what backup heat you have. Electric heat strips, a gas furnace (dual-fuel), or none at all. It changes what you’ll do later. If you’re not sure, check the emergency heat guide or ask your HVAC company.
  6. Test your CO detectors and replace thermostat batteries. The CDC recommends battery-operated or battery-backup carbon monoxide detectors near every sleeping area. That’s critical if you’ll be using a generator or gas appliances during an outage.


During an Ice Storm: Let the Heat Pump Work

A layer of ice or frost on your heat pump during a storm is not automatically a problem. Heat pumps run a defrost cycle that warms the outdoor coil and melts ice off. You may see steam rising and hear a “whoosh” while it happens. That’s normal. Learn more in our guide to steam and defrost mode.

So don’t turn your heat pump off just because it’s icy outside. Let it keep heating and defrosting.

But freezing rain is the toughest test a heat pump faces. Lennox notes that long periods of freezing rain, sleet, or heavy wet snow can overwhelm the defrost system. When ice builds faster than the defrost cycle can melt it, it’s time to step in.

Commercial HVAC Services

Should You Switch to Emergency Heat During an Ice Storm?

This is the most common question we hear during a storm. Here’s a simple way to decide:

Switch to Emergency Heat (EM Heat) if:

  • Ice covers the whole unit, including the sides and top.
  • Ice is blocking the fan, or you hear the fan blades hitting ice.
  • The unit is running but little or no warm air is reaching your vents.
  • Thick ice keeps building even after defrost cycles.


Keep normal Heat mode if:

  • There’s a light coat of frost or ice that clears during defrost
  • Your home is staying warm
  • The fan is spinning freely


Why switch? Emergency heat turns the outdoor unit off and heats your home with backup heat only, usually electric heat strips. That stops the fan from grinding against ice, and Lennox notes it lets the outdoor unit thaw while your home stays warm.

Why not use it all the time? Emergency heat is expensive to run. Heat strips use far more electricity than the heat pump itself. See what emergency heat costs per day. Switch back to normal heat once the ice is gone and the fan can spin freely.

Should You Cover Your Heat Pump?

Covering the top: okay. Wrapping the whole unit: no.

  • A top-only cover or deflector (a sloped piece of plywood or a manufacturer snow guard, mounted above the unit) can keep falling ice and icicles from landing on it. Lennox lists a top-only snow guard as a prevention option.
  • Never wrap the sides in a tarp, plastic, or a full cover while the system might run. Lennox warns that covering the sides blocks airflow. A heat pump that can’t breathe can be damaged, and a wrapped unit can trap moisture.
  • Don’t stack anything against the unit, including shoveled snow.


How to Clear Ice Safely

If ice is building up and you want to help it along:

  1. Switch the thermostat to Emergency Heat (or off, if you don’t have backup heat).
  2. Turn off power at the outdoor disconnect or breaker before touching the unit.
  3. Brush off loose snow and sleet from the top and around the base with a soft broom or your hands.
  4. Let the rest melt naturally. Lennox says thawing usually takes 2–4 hours above freezing. If it doesn’t thaw within 6–8 hours or refreezes quickly, call a technician.


Never:

  • Chip, pry, or hammer the ice. Lennox warns that tools can damage the coils, fins, and fan blades.
  • Pour hot water on it. The sudden temperature change can crack parts.
  • Use a heat gun, torch, or space heater on the unit.
Heat Pump in an Ice Storm or Power Outage

During a Power Outage

When the power goes out, your heat pump and its backup heat strips both stop. Here’s what to do:

  1. Set the thermostat to Off. This keeps the system from trying to start up the moment power flickers back on.
  2. Turn off the heat pump’s breaker or outdoor disconnect. Storms often bring power that blinks on and off. Switching off the breaker protects the system from repeated start attempts while power is unstable.
  3. Stay warm safely. Close off unused rooms, layer up, and use a warming shelter if your home gets too cold.
  4. Never heat your home with a gas oven, grill, camp stove, or generator indoors.


Can You Run a Heat Pump on a Generator?

Sometimes. It depends on the generator’s size and how it’s connected:

  • A heat pump can’t be plugged into a portable generator with an extension cord. It’s hardwired.
  • Running it from a generator requires a transfer switch or interlock kit installed by a licensed electrician. These keep your generator from sending power back into the utility lines (“backfeeding”), which can seriously injure line workers.
  • The generator has to be big enough to start the compressor. Heat strips draw a lot of power too, and many portable generators can’t handle them.


Generator safety (from the CDC):

  • Run generators outdoors only, more than 20 feet from windows, doors, and vents.
  • Never run a generator in a garage, even with the door open.
  • Have working CO detectors inside.


How to Restart Your Heat Pump After the Power Comes Back

This is the step most homeowners skip, and it matters most.

When a heat pump sits without power in cold weather, the compressor and refrigerant get cold. Starting the compressor right away can strain it. That’s why some manufacturers recommend running on emergency heat for a while after an outage before going back to normal heat.

For example, a Carrier heat pump owner’s manual says to:

  • Switch to Emergency Heat if the power to your outdoor unit has been off for more than 30 minutes
  • Leave it on Emergency Heat for as long as the power was off, but no more than 12 hours
  • If you don’t know how long the power was off, leave it on Emergency Heat for 8 hours


Rules vary by brand and model, so check your own owner’s manual. Here’s a safe general sequence:

  1. Wait until power is stable. Give it a few minutes after the lights come back on for good.
  2. Check the outdoor unit. Make sure the fan isn’t blocked by ice or debris, and nothing has fallen on the unit.
  3. Turn the breaker or outdoor disconnect back on.
  4. Set the thermostat to Emergency Heat if the outage lasted more than 30 minutes, for the length of time your manual recommends.
  5. Switch back to normal Heat mode after that time and set your normal temperature.
  6. Watch and listen for the first 15 minutes. Warm air should come out of the vents, and the outdoor unit should run smoothly.


If the system won’t start, see our guide to resetting your HVAC system, or call a technician.

What’s Different for Dual-Fuel and Ductless Systems

  • Dual-fuel (heat pump + gas furnace): your backup heat is the furnace, not heat strips. The furnace’s blower and controls still need electricity, so it won’t run during an outage either. After power returns, the emergency heat setting typically runs the furnace. Check your manual for your system’s restart steps.
  • Ductless mini-splits: many have no built-in backup heat. During a storm, keep the outdoor unit clear and follow the manufacturer’s manual for restarting after an outage. If your ductless system has trouble in cold weather, it may be worth comparing your options. See ducted vs. ductless heat pumps.
Heat Pump in an Ice Storm or Power Outage

Warning Signs After the Storm (When to Call a Pro)

After an ice storm or outage, call a technician if your heat pump:

  • Trips the breaker when it starts
  • Makes grinding, screaming, or banging noises
  • Has a fan that won’t spin after the ice melts
  • Blows cool air in Heat mode (see why a heat pump isn’t blowing hot air)
  • Refreezes quickly after thawing
  • Has bent fins, a dented cabinet, or damaged refrigerant lines from falling ice or branches
  • Runs on AUX or emergency heat constantly after you’ve switched back to normal heat


If any of these happen, turn the system off and get it checked. Running a damaged heat pump can turn a small repair into a compressor replacement.

RHCC repairs heat pumps for homeowners in Vancouver, Battle Ground, Camas, Ridgefield, and the greater Portland area. If your heat pump won’t restart, is making strange noises, or got hit by falling ice, call 360-984-1853 or request heat pump repair.

FAQs

Should I turn off my heat pump during an ice storm?

Not just because it’s icy. Heat pumps defrost themselves and can handle light ice. Switch to Emergency Heat if ice covers the unit or blocks the fan. If the power goes out, set the thermostat to Off and switch off the heat pump’s breaker until power is stable.

Should I use emergency heat during an ice storm?

Only when the outdoor unit is badly iced: ice blocking or hitting the fan, the whole unit encased, or no warm air coming out. Emergency heat lets the outdoor unit thaw while your home stays warm, but it costs more to run, so switch back to normal heat once the ice clears.

How do I cover my heat pump in an ice storm?

Only cover the top. A sloped board or a manufacturer-approved snow guard mounted above the unit can deflect falling ice. Never wrap the sides in a tarp or cover, which blocks airflow and can damage the system.

Can I run my heat pump on a generator?

Only if a licensed electrician has installed a transfer switch or interlock kit and the generator is large enough to start the compressor. Never plug a generator into your home’s wiring without one. Run generators outdoors, more than 20 feet from windows, doors, and vents, as the CDC advises.

Why should I wait before switching back to normal heat after a power outage?

When a heat pump sits without power in the cold, the compressor gets cold. Some manufacturers, including Carrier in one owner’s manual, recommend running on emergency heat for about as long as the power was off (8 hours if you don’t know, no more than 12) before going back to normal heat. Check your own manual for your model’s rule.

Can a heat pump freeze up in cold weather?

Yes. Light frost is normal, and the defrost cycle clears it. Freezing rain, sleet, water dripping from gutters, or a failed defrost control can cause heavy ice that the system can’t clear on its own. That’s when you switch to emergency heat and call a technician if it doesn’t thaw.

Your Ice Storm Heat Pump Checklist

Before: clear 2 feet around the unit, fix dripping gutters, check overhead branches, know your breaker, test CO detectors. During the storm: let defrost work, switch to emergency heat only if the unit is badly iced, cover the top only, never chip ice. During an outage: thermostat off, breaker off, generators outside and 20+ feet away. After: power stable, check the unit, breaker on, emergency heat for the time your manual says, then normal heat. Watch for warning signs.

Storms are part of life here, but a damaged heat pump doesn’t have to be. If your system isn’t running right after the ice melts, call RHCC at 360-984-1853.

Related Blogs

Replacing an oil furnace with a heat pump usually makes strong financial sense in Vancouver, WA, because local electricity is cheap and heating oil is not. The bigger job may be your oil tank, not the heat pump. Washington has a state program that can help pay for tank work, but you must apply before […]